Gold Member Since 2008
Audited Supplier
Nanjing Foinoe Co., Ltd.

Veterinary Monitor, Multi-Parameter Patient Monitor, Vet Patient Monitor Price manufacturer / supplier in China, offering 12 Inch Portable Veterinary Monitor, Hot Sale Ce Approved Cheap Chair Mounted Dental Unit, Electric Operation Table (electric hydraulic) and so on.

(/ )

Supplier Homepage Product 12 Inch Portable Veterinary Monitor

12 Inch Portable Veterinary Monitor

This product is currently unavailable, but you may contact the supplier directly, for further interest.
Basic Info
  • Model NO.: PMV-12A
  • Animal Anesthesia Machine Control Method: Electronic Control
  • Trademark: Foinoe
  • Origin: Nanjing, Jiangsu
  • Breathing Pattern: Auto-Control
  • CE: Approved
  • Specification: CERTIFICATES: CE, ISO13485, ISO9001
Product Description
Feature
12.1high resolution TFT LCD display
One level menu, easy to use
Maximum 720 hours tabular and graphic trends of all parameters
Bulit-in thermal recorder and battery
Suitable for Animal
OxyCRG Dynamic View and short Trend Coexist Display
Standard network interface, can connect to the central monitor system
Standard
12.1 inch LCD, 5 ECG leads, RESP, NISP, PR, SPO, 2-TEMP, Rechargable Battery
Optional
Thermal Recorder, 2-IBP, ETCO2
Specification
ECG
Lead Mode: 3/5 Leads
Gain: X0.25, x0.5, x1, x2, auto
Heat Rate: 15~300bpm(adult), 15~350bpm(neonatal)
Accuracy: ± 1%
Resolution: 1 bpm
ST Segment Range: -2.0~ +2.0 mV
ARR Detecing: Yes
Pacemaker: Yes
Electrode offset potential: ± 300mV
Leakage Current: < 10 uA
Bandwidth
Surgery: 1-15 Hz
Monitor: 0.5-35 Hz
Diagnostic: 0.05 ~ 100Hz

RESPIRATION
Method: Impedance between R-F(RA-LL)
Base line Impedance Range: 0-2.5 K
Bandwith: 0.3 ~ 2.5 Hz
Measuring Range
Neo/Ped: 0-150 rpm
Resolution: 1 rpm
Accuracy: ± 2 rpm
Apnea Alarm: 10-40 S

SPO
Measuring And Alarm Range: 0 ~ 100%
Resolution: 1%
Accuracy: 70% ~ 100% ± 2 %
0% ~ 69% unspecified
Actualization interval: About 1 Sec.
Alarm Delay: 10sec.

NIBP
Word Mode: Manual, Auto, Continuous

IBP
Lable: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART: 0 ~ 300 mmHg
PA: -6 ~ 120 mmHg
CVP/RAP/LAP/ICP: -10 ~ 40 mmHg
P1/P2: -10 300mmHg
Press Sensor
Sensitivity: 5uV/V/ mmHg
Resolution: 1 mmHg
Accuracy: ± 2% or ± 1% mmHg, which great
Actualization interval: About 1 secretary

TEMPERATURE
Channel: 2
Measuring and Alarm Range: 0~ 50º C
Resolution: 0.1º C
Accuracy: ± 0.1 º C
Actualization interval: About 1 Sec
Average Time Constant: < 10 Sec
Send your message to this supplier
Avatar
Mr. Bob Jiang
Director
*From:
To: Mr. Bob Jiang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now