Gold Member Since 2008
Audited Supplier
Nanjing Foinoe Co., Ltd.

Prices of Ultrasound Machine, Color Doppler, Portable Doppler Ultrasound Machine manufacturer / supplier in China, offering U3 Full Digital CE and FDA Approved Prices of Ultrasound Machine, Hot Sale Ce Approved Cheap Chair Mounted Dental Unit, Electric Operation Table (electric hydraulic) and so on.

(/ )

Supplier Homepage Product U3 Full Digital CE and FDA Approved Prices of Ultrasound Machine

U3 Full Digital CE and FDA Approved Prices of Ultrasound Machine

This product is currently unavailable, but you may contact the supplier directly, for further interest.
Basic Info
  • Model NO.: U3
  • Type: Color Doppler
  • Group: Middle-aged and Old
  • Trademark: Foinoe
  • Origin: China
  • Classification: Imaging Diagnostic Equipment
  • Certification: CE, FDA, ISO13485
  • FDA,CE: Certificated
  • Specification: FDA CE
Product Description
 U3  Full digital ce and fda approved prices of ultrasound machine
U3 Full Digital CE and FDA Approved Prices of Ultrasound Machine
Accord with Ergonomic design
Human console design, distinguished by frequency of use and functionality to
optimize keyboard design
High-resolution LCD display
Flexible display with free arm
Laser carved buttons are noble, elegant, practical
 
System Features
Systemictype,includingabdomen,obstetrics,gynecology,blood vessel , small parts cardiology , urological, neonatal and paediatrics.
Contains 2D/CFM/PDI/PW/CW/M and other scan mode, and provides excellent resolution and sensitivity.
Supportconvexprobe,linearprobe,phasedarrayprobeand transvaginal probes.
IntegratednetworkultrasoundworkstationsupportsDICOM transmission.
Embeddedcomputersystemsenablesystem integratetowith security, stability and high-speed operation together.
 
General specifications:
POWER SUPPLY: 100/230V(±10%)60/50Hz
Max Power: 350VA
Display: 15inch high definition de-lnterlace flicker-free medical monitor
Up/down gradient (±15 degree),left/right rotation(±75degree)
 
System Overview:
Application
Systemic type: Abdomen, Obstetrics, Gynecology, Cardiology, Blood vessel,
Urological, Small parts, Breast, Pediatrics, Neonatal imaging, Fetal cardiac
imaging, Puncture, etc.
 
Probe scanner parameter:
Convex probe
Scan angle: 73°
Arrays: 128
Frequency area: 2.5 MHz-5.0 MHz
5 segment frequency
The largest scanning depth: 180mm
Blind area: ≤8mm
Resolution: Axial resolution ≤ 2mm, lateral resolution ≤ 3mm
Geometric position precision: horizontal direction ≤ 10mm, vertical
direction≤ 15mm
 
Liner probe
Arrays: 128
Frequency area: 5.0MHz-10.0MHz
5 segment frequency
The largest scanning depth: 120mm
Blind area: ≤3mm
Resolution: Axial resolution ≤ 1mm, lateral resolution ≤ 2mm
Geometric position precision: horizontal direction ≤ 10mm, vertical direction≤ 5mm
 
Transvaginal Convex probe
Scan angle: 149°
Arrays: 128
Frequency area: 4.5MHz-9.0MHz
5 segment frequency
The largest scanning depth: 80mm
Blind area: ≤7mm
Resolution: Axial resolution ≤ 1mm, lateral resolution ≤ 2mm
Geometric position precision: horizontal direction ≤ 3mm, vertical direction≤3mm
Operation Mode: B Mode, M Mode, CFM, PDI, PW, CW, THI
Probe port: Three activation probe prot
PAL-D Network
DVD,USB
Digital, Video printer
Laser printer
S-Video,AV CD-R/W
Storage
Image storage, cineloop storage , preview(≥300frame) ,
Disk storage capacity≥120G
Puncture Guide
The angle of the puncture guide line can be adjustable and pre-setting
Language:
Can instantly switch the whole Chinese / English display
 
System Setting:
Language: Chinese, English
Date format:: yyyy-mm-dd,mm-dd-yyyy or dd-mm-yyyy selectable
Time format: 24 hours
Body mark: ≥95 types
Printer setup: Video printer, Report printer (laser printer, inkjet printer)
Image storage format: JPEG,BMP
Presetting mode: 10 groups of setting items (including 4 groups of user defined items)
Test Note presetting: each group of presetting can set for 10 test constants (Each test note can be 15 characters at most)
OB Table, Gestational Age setting: Setting area of OB measurement, method,checking and creating gestational age table and growth table which user defined
Transmitted power setting
Sampling volume setting
PRF setting
Filtering parameters setting
Pulse period setting
Doppler angle setting
Doppler speed setting
Pulse period setting
Proseudo Setting
Screen protection function
Freezing function
Foot switch setting function
System improvement
MF maintenance function
 
Ultrasonic image technology:
1. High accuracy DBF technology
DBF can clean the noise of valve efficiently; also improve the space resolving power and comparing power, showing all the tissue structures carefully.
2. DFS technology
Adapting and controlling the transmission and receiving frequency of near field to the distant field, consolidating the strong penetrating power and high definition image perfectly.
3. High accuracy DRF technology
High accuracy point to point focusing in all the field, showing the real and smoothly tissue information
4. Wide screen imaging technology
According to the characters of different people, choose the best central frequency what the user want.
5. Image optimum processing technology
According to the receiving tissue signals, optimize the digital parameters automatically in order to show the perfect ultrasonic image.
6. Vascular Imaging technology
According to the receiving Doppler signals, adopt the most suitable filtering way for
Preventing the filters, consolidate the penetrating power and sensitivity perfectly and show the best blood image.
7. Doppler Imaging technology
Enhance the weak Doppler signals, by using complicated digital technology to
enhance the spectral signals to make the Doppler sensitivity and display effect be improved.
8. THI technology
Transmitting the low frequency of ultrasonic, receiving the high frequency signals for
Making image, in this way, it will protect penetrating power, enhance the resolving power of image and clean the pseudomorphism.
 
Image Processing:
Beam processing:
Full-digital multi-beam forming technology, real-time dynamic receiving focusing point by point, continuous dynamic focusing,variable aperture real-time dynamic imaging, real-time dynamic beam apodization, dynamic filter, NC dynamic frequency scan.
 
Image preprocessing:
Main Gain: 0-100, can be adjusted
TGC: 8 segment TGC adjustment
Sound output: low, medium and high levels adjustable
Gray Value: 0 to 15 grades can be adjusted
Image processing:
Edge enhancement: 5 grades can be adjusted
Frame Average: 6 grades can be adjusted
Line Average: 3 grades can be adjusted
Gamma corrections: 0.1-8 can be adjusted step by step
Contrast Adjustment: 0~100
Brightness adjustment: -50~+50
 
Scanning Parameter
B Mode
Sound Power: High, medium and low levels adjustable
Gain: 0-100 B
CMRR: 120dB
M Mode
M Sound Power: High, medium and low levels adjustable
M Gain: 0-100
M Scanning speed: High, medium and low levels adjustable
M Sampling line can be adjusted and visual
CFM Color Doppler mode
CFM Gain: 0-100
CFM Filter: 8 steps
CFM color sliding: 3 steps
Max PRF: 7 KHz
Min PRF:0.35kHz
PDI Power Doppler Mode
PDI Gain: 0-100
PDI Filter: 8 steps
PDI color sliding: 3 steps
Max PRF: 7 KHz
Min PRF: 0.35kHz
PW Pulsed Spectral Doppler
PW Gain:0-100
PW CMRR: 4 steps
PW Filter: 4 steps
PW Noise Reduction:4 steps
Sample volume width:0.5-30mm
Angle adjustment
Baseline adjustment: 9 steps
Max PRF(Speed): 7kHz
Min PRF (Speed): 1kHz
Max detection rate: 21m/s (7.18m/s,0°)
Min detection rate: 0.05cm/s
 
Image Display
256 grayscale display two-dimensional images
Gray Histogram
Image Rotation: left/right, up/down,90°rotation
Depth: 3-24cm, can be adjusted
Focusing emission: max 8 focus point (The focus point quantity depends on the probe type and depth)
Receive Focusing: Continuous dynamic focusing, dynamic aperture.
Dynamic Range: ≥120dB
Real Time Zoom: Six times
M Mode Speed: 3
Scanning Angle: 3 angle (Only convex)
TGC Line
Black/White Correlation
Video Output: Auto-select NTSC or PAL video format
 
Measurement/ Calculation
 
General Measurement
B Mode Measurement: Distance, Area, Girth, Volume, Angle, Rate.
M Mode Measurement: Slope, Rate, Distance, HR, Time.
D Mode Measurement: Blood Flow Doppler, speed, Acceleration, Time, Rate,
Drag Index, Cardiac Output.
 
Gynecology Measurement and Analysis
Measurement: Venter, Endometrium, Ovary, Uterine neck and Follicular.
 
Obstetrical Measurement and Analysis
GS,CRL,LV,BPD,OFD,HC,TAD,LVW,HW,TCD,IOD,OOD,BD,
APTD,TTD,AC,APD,FTA,HL,ULNA,RAD,FL,TIB,FIB,APTDxTTD,
CLAV,Buttocks Growth Anomally.
Measurement: GA, Fetal Weight, EDD, OB Carve.
 
Urology Measurement and Analysis
Prostate Volume, Bladder Volume, RUV, TZV.
 
Measurement Report
OB Report, Gynecology Report, Heart Report, Urology Report and other
reports.
Automatic Save Measurement Result and Report.
 
Marks
More than 95 body marks
Text mark support.
Arrow mark support.
 
Description
Standard Configuration U3 main unit Contains one convex probe and one linear probe as standard configuration

Options Transducers Convex array transducer(C3.5M/R60/156P)
Linear array transducer(L7.5M/L38/156P)
Transvaginal ARRAY transducer(L6.5M/R10/156P)
Micro-convex array transducer(C3.5M/R20/156P)
Phased array transducer(P16/3.0M/156P)
Accessories Video printer SONY-UP897
laser printer Lenovo LJ-2400L
Gel(250ML)
CD/DVD ROM
U3 Full Digital CE and FDA Approved Prices of Ultrasound Machine
U3 Full Digital CE and FDA Approved Prices of Ultrasound Machine
 

Send your message to this supplier
Avatar
Mr. Bob Jiang
Director
*From:
To: Mr. Bob Jiang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now