Basic Info
  • Model NO.: FM-21
  • Type: Patient/Fetal/Maternal Monitor
  • Group: Infants and Young Children
  • Trademark: FoiNoe
  • Origin: Nanjing, Jiangsu
  • Classification: Physiological Functions of Diagnosis and Monitoring Equipment
  • Certification: CE, FDA, ISO13485
  • CE: Certificated
  • Specification: CERTIFICATES: CE, ISO13485, ISO9001
Product Description
Main features
12.1" colour TFT highlight screen.
Reliable high sensitive 12-element pulse doppler transducer. Easy to capture signal.
Rotatable screen, suit to watch from different direction.
Built in high speed thermal printer, printing width could be 210mm, 150mm or 112mm.
5 different style of operation screen, according to the choose of user
Optional function: Twins monitoring function, automatic fetal movements detection, AFM waveform displayable
Automatic monitoring mode, parameters configurable
Linux operation system, stable, easy to operate.
48 hours monitoring data playback
Rechargeable Li-ion Battery
Built-in network capability, support wireless network

Standard configuration
CFM-21 Venus B/C/D main unit
Bulit-in rechargeable lithium battery
Ultrasonic Doppler transducer
TOCO Doppler transducer
Fetal movement marker
Belts
Coupling gel
Thermal paper
(ECG cable, Sp02 sensor, NIBP cuff, TEMP probe for Venus D additionally)
Options
Twins monitoring
Automatic fetal movement detection
AFM waveform displayable
Wall mount
Aluminum trolley
ECG
Heart rate range: 30-300bpm
Accuracy: +-1bpm/+-1%
Leads: I, II, III, avr, avl, avf, v
Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
Gain selection: *0.25, *0.5, *1, *2
Resolution: 1bpm
Operation mode: Diagnostic, monitor, surgery
NIBP
Operation Mode: Manual/Automatic
Measurement Unit: MmHg/Kpa selectable
Test interval: 0-480 minutes
Measurement range: Systolic: 60-240mmHg
Mean: 40-200mmHg
Diastolic: 30-180mmHg
Resolution: 1mm Hg
Accuracy: +-3%
Pulse rate range: 40-240bpm
Over-pressure Protection: Yes
SPO2
Range: 0%-100%
Resolution: 1%
Accuracy: +_2%
Pulse range: 30-250bpm
TEMP
TEMP range: 26.0° C-45.0° C
Resolution: 0.1° C
Accuracy: +_0.2° C


FHR
Ultrasound sensor: 12 elements doppler transducer
Ultrasound frequency: 1MHz(+-5%)
Ultrasound power: ≤ 3Mw/cm2
BPM range: 60-210bpm
Resolution: 1bpm
Accuracy: +_1bpm/+_1%

TOCO
Measurement range: 0-100 relative units
Resolution: 1 Count
Accuracy: ≤ +_5%

RESP
Mesurement range: 1-99rpm
Resolution: 1rpm
Accuracy: +_2rpm
FM
Push marker
Automatic Fetal Movements Detection is optional